Caracterização dosimétrica de gel tipo VIPARnd através de técnicas ópticas para feixes de raios x de 6mv usados em radioterapia externa

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2015.

Main Author: Dias, Juliana Rosada
Other Authors: Ceschin, Artemis Marti
Format: Dissertação
Language: Português
Published: 2015
Subjects:
Online Access: http://repositorio.unb.br/handle/10482/19010
http://dx.doi.org/10.26512/2015.06.D.19010
Tags: Add Tag
No Tags, Be the first to tag this record!
id ir-10482-19010
recordtype dspace
spelling ir-10482-190102018-10-25T21:42:59Z Caracterização dosimétrica de gel tipo VIPARnd através de técnicas ópticas para feixes de raios x de 6mv usados em radioterapia externa Dias, Juliana Rosada Ceschin, Artemis Marti Lopes, Roseany de Vasconcelos Vieira Dosimetria Gel polimérico Radioterapia Engenharia médica Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2015. Neste trabalho as principais características ópticas do dosímetro gel VIPARnd foram avaliadas para feixes de fótons de 6 MV usados em radioterapia externa. O espectro de absorvância do dosímetro gel foi avaliado com espectrofotometria óptica e através do processamento de imagens fotográficas adquiridas com câmera de sensor CMOS para doses de 0 a 50 Gy. Foram avaliadas duas soluções com concentrações diferentes dos componentes do gel. Os dados obtidos através da espectrofotometria óptica mostram que o VIPARnd apresenta pico de absorção entre 300 a 320 nm dependendo da dose absorvida. O aumento da dose absorvida causa aumento na absorvância do VIPARnd. As curvas de dose resposta foram analisadas em função do máximo de absorção e também através da área sob o espectro. A solução 1 apresenta região linear de 3 a 20 Gy e a solução 2 para a região de 0,5 a 5 Gy. A repetitividade entre amostras de um mesmo lote ficou em 0,5% e a reprodutibilidade inter-lotes em 5 %. A estabilidade do gel VIPARnd foi mantida para um tempo pós-irradiação de pelo menos 15 dias. As imagens fotográficas foram adquiridas em escala RGB, a partir da análise de absorção óptica foi suposto que a componente azul apresentasse maior resposta para determinação da dose absorvida o que de fato foi comprovado com os dados obtidos. Para este caso a faixa de resposta linear obtida foi entre 3 e 20 Gy para a solução 1 e entre 0,5 e 20 Gy para a solução 2. Como testes adicionais, foi analisado a curva de dose resposta a partir de imagens de tomografia computadorizada, assim como o estudado da aplicação do gel para medidas de perfil de campos pequenos e PDP para feixes de raios X de 6 MV e a resposta do gel à irradiações com fonte de irídio 192 usadas em braquiterapia de alta taxa de dose. O bom desempenho do dosímetro VIPARnd nos testes realizados indica que este pode ser utilizado na avaliação tridimensional da dose em tratamento radioterápicos. This work aims to evaluate the optical characteristics of a dosimeter VIPARnd for 6 MV photon beam used in radiotherapy. The absorbance spectrum of irradiated gel dosimeter was evaluated with optical spectrophotometer techniques and with CMOS camera readout for dose range of 0 to 50 Gy. Two solutions with different concentration were evaluated. Data shows that the VIPARnd has a maximum absorbance at 300 to 320 nm depending on the absorbed dose. The absorbed dose increases the absorbance values of VIPARnd. The dose response curves were obtained by the peak value and the relative area under of absorbance curve. The solution 1 shown interval of linearity from 3 to 20 Gy and the solution 2 from 0,5 to 5 Gy. The repeatability and inter-batch reproducibility of gel response were 0,5 % and 5% respectively. Temporal analysis indicates that the gel dosimeter has no significant variation in absorbance peak for the post irradiation times until 15 days. The CMOS camera readouts were obtained in RGB color, the absorbance measurements suggest a major response of dose for blue matrix verified with data. The dose response curve for blue component showed interval of linearity from 3 to 20 Gy for solution 1 and from 0,5 to 20 Gy. Additional tests were performed to determine the dose response with X-ray computed tomography, analyses of dose profile measurements for small field radiation therapy and percentage depth dose for 6 MV photon beam and gel response for irradiation with Iridium 192 source in high dose rate brachytherapy. These characteristics indicate that the presented VIPARnd polymer gel could be helpful for radiotherapy dosimetry. 2015-12-21T11:38:43Z 2015-12-21T11:38:43Z 2015-12-21T11:38:43Z 2015-06-23 Dissertação DIAS, Juliana Rosada. Caracterização dosimétrica de gel tipo VIPARnd através de técnicas ópticas para feixes de raios x de 6mv usados em radioterapia externa. 2015. xv, 68 f., il. Dissertação (Mestrado em Sistemas Eletrônicos e de Automação)—Universidade de Brasília, Brasília, 2015. http://repositorio.unb.br/handle/10482/19010 http://dx.doi.org/10.26512/2015.06.D.19010 Português Acesso Aberto A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data. application/pdf
institution REPOSITORIO UNB
collection REPOSITORIO UNB
language Português
topic Dosimetria
Gel polimérico
Radioterapia
Engenharia médica
spellingShingle Dosimetria
Gel polimérico
Radioterapia
Engenharia médica
Dias, Juliana Rosada
Caracterização dosimétrica de gel tipo VIPARnd através de técnicas ópticas para feixes de raios x de 6mv usados em radioterapia externa
description Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2015.
author2 Ceschin, Artemis Marti
format Dissertação
author Dias, Juliana Rosada
author_sort Dias, Juliana Rosada
title Caracterização dosimétrica de gel tipo VIPARnd através de técnicas ópticas para feixes de raios x de 6mv usados em radioterapia externa
title_short Caracterização dosimétrica de gel tipo VIPARnd através de técnicas ópticas para feixes de raios x de 6mv usados em radioterapia externa
title_full Caracterização dosimétrica de gel tipo VIPARnd através de técnicas ópticas para feixes de raios x de 6mv usados em radioterapia externa
title_fullStr Caracterização dosimétrica de gel tipo VIPARnd através de técnicas ópticas para feixes de raios x de 6mv usados em radioterapia externa
title_full_unstemmed Caracterização dosimétrica de gel tipo VIPARnd através de técnicas ópticas para feixes de raios x de 6mv usados em radioterapia externa
title_sort caracterização dosimétrica de gel tipo viparnd através de técnicas ópticas para feixes de raios x de 6mv usados em radioterapia externa
publishDate 2015
url http://repositorio.unb.br/handle/10482/19010
http://dx.doi.org/10.26512/2015.06.D.19010
_version_ 1641988008670396416
score 13.657419