Efeito de diferentes intervalos de recuperação sobre o desempenho isocinético de indivíduos com doença de Parkinson

Tese (doutorado)—Universidade de Brasília, Faculdade de Educação Física, Programa de Pós-Graduação em Educação Física, 2019.

Main Author: Santos, Tácio Rodrigues da Silva
Other Authors: Lima, Ricardo Moreno
Format: Tese
Language: Português
Published: 2019
Subjects:
Online Access: http://repositorio.unb.br/handle/10482/35247
Tags: Add Tag
No Tags, Be the first to tag this record!
id ir-10482-35247
recordtype dspace
spelling ir-10482-352472019-08-07T19:59:43Z Efeito de diferentes intervalos de recuperação sobre o desempenho isocinético de indivíduos com doença de Parkinson Santos, Tácio Rodrigues da Silva Lima, Ricardo Moreno Parkinson, Doença de Parkinson, Doença de - reabilitação Força muscular Desempenho isocinético Treinamento de força Tese (doutorado)—Universidade de Brasília, Faculdade de Educação Física, Programa de Pós-Graduação em Educação Física, 2019. Introdução: O déficit de força muscular em indivíduos com doença de Parkinson resulta em prejuízo ao desempenho funcional. Entretanto, nestes casos, o treinamento resistido melhora a força muscular e o desempenho funcional. Para que estes benefícios ocorram, é necessário que haja uma adequada organização das variáveis agudas do treinamento resistido. A este respeito, a literatura científica se mostra especialmente limitada no que tange o intervalo de recuperação. Objetivo: Analisar o efeito de diferentes intervalos de recuperação sobre o desempenho isocinético de indivíduos com doença de Parkinson. Materiais e Métodos: O Grupo Parkinson (n=11; 69,73 ± 5,72 anos; 1,73 ± 0,05 m; 74,80 ± 13,10 kg; 24,98 ± 4,62 kg/m²) e o Grupo Controle (n= 11; 73,91 ± 5,86 anos; 1,70 ± 0,05 m; 75,97 ± 12,04 kg; 26,20 ± 3,00 kg/m²) foram submetidos a duas avaliações do desempenho isocinético compostas por três séries de 10 repetições a 60°/s, uma com um e outra com dois minutos de recuperação. O melhor desempenho dos grupos foi comparado com teste-t independente. O desempenho de cada grupo ao longo das séries com os diferentes intervalos de recuperação foi avaliado com análise de variância de dois fatores e três níveis. Adicionalmente, o tamanho do efeito foi calculado. Resultado: O Grupo Parkinson apresentou menor Pico de Torque Absoluto (p=0,04; tamanho do efeito=-1,07), Torque a 18 ms Absoluto (p=0,04; tamanho do efeito=-1,07), Trabalho Total Absoluto (p=0,01; tamanho do efeito:-1,24), Trabalho Total Relativo (p=0,02; tamanho do efeito=-1,37), Potência Média Absoluta (p=0,02; tamanho do efeito=-1,32), e Potência Média Relativa (p=0,02; tamanho do efeito=-1,45). Os grupos não diferiram em Pico de Torque Relativo, Torque a 18 ms Relativo, e Fadiga do Trabalho. Ao longo das séries, não houve diferença os entre os intervalos no Pico de Torque, Torque a 18 ms, Trabalho Total, Potência Média, e Fadiga do Trabalho. Conclusão: Apesar do menor desempenho isocinético de indivíduos com doença de Parkinson, um intervalo com um minuto de recuperação é suficiente para a manutenção de desempenho tanto para indivíduos com doença de Parkinson como para seus pares controle. Background: Muscle weakness in individuals with Parkinson's disease results in consistent funcional impairment. Furthermore, in theses cases, resistance training improves muscle strength and funcional performance. To secure such benefits, it is necessary make an adequate organization of the acute resistance training variables. In this regard, there is a gap in scientific literature about the rest interval. Purpose: To analyze the effect of dirrerent rest intervals over the isokinetic performance of individuals with Parkinson's disease. Material and Methods: Parkinson's Group (n=11; 69,73 ± 5,72 years; 1,73 ± 0,05 m; 74,80 ± 13,10 kg; 24,98 ± 4,62 kg/m²) and Control Group (n= 11; 73,91 ± 5,86 years; 1,70 ± 0,05 m; 75,97 ± 12,04 kg; 26,20 ± 3,00 kg/m²) took part in two isokinetic evaluations with three sets of 10 repetitions at 60°/s, with one and two minutes between the sets. Indepentent t-tests compared the best performance of the groups, and fatorial analyses of variance compared the performance of each group across the sets with diferente rest intervals. Aditionally, the effect size was calculed. Results: Parkinson Group presented lower Absolute Peak Torque (p=0,04; effect size=-1,07), Absolute Torque at 18 ms (p=0,04; effect size=-1,07), Absolute Total Work (p=0,01; effect size:-1,24), Relative Total Work (p=0,02; effect size=-1,37), Absolute Average Power (p=0,02; effect size=-1,32), and Relative Average Power (p=0,02; effect size=-1,45). The groups did not differ on Relative Peak Torque, Relative Torque at 18 ms, and Work Fatigue. Across the sets, there was no difference between the rest intervals for both groups on Peak Torque, Torque at 18 ms, Total Work, Average Power, and Work Fatigue. Conclusion: Despite the lower isokinetic performance of individuals with Parkinson’s disease, rest intervals of one minute are adequate for both individuals with Parkinson’s disease and their matched controls. 2019-08-07T19:59:01Z 2019-08-07T19:59:01Z 2019-08-07 2019-02-28 Tese SANTOS, Tácio Rodrigues da Silva. Efeito de diferentes intervalos de recuperação sobre o desempenho isocinético de indivíduos com doença de Parkinson. 2019. 85 f., il. Tese (Doutorado em Educação Física)—Universidade de Brasília, Brasília, 2019. http://repositorio.unb.br/handle/10482/35247 Português Acesso Aberto A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data. application/pdf
institution REPOSITORIO UNB
collection REPOSITORIO UNB
language Português
topic Parkinson, Doença de
Parkinson, Doença de - reabilitação
Força muscular
Desempenho isocinético
Treinamento de força
spellingShingle Parkinson, Doença de
Parkinson, Doença de - reabilitação
Força muscular
Desempenho isocinético
Treinamento de força
Santos, Tácio Rodrigues da Silva
Efeito de diferentes intervalos de recuperação sobre o desempenho isocinético de indivíduos com doença de Parkinson
description Tese (doutorado)—Universidade de Brasília, Faculdade de Educação Física, Programa de Pós-Graduação em Educação Física, 2019.
author2 Lima, Ricardo Moreno
format Tese
author Santos, Tácio Rodrigues da Silva
author_sort Santos, Tácio Rodrigues da Silva
title Efeito de diferentes intervalos de recuperação sobre o desempenho isocinético de indivíduos com doença de Parkinson
title_short Efeito de diferentes intervalos de recuperação sobre o desempenho isocinético de indivíduos com doença de Parkinson
title_full Efeito de diferentes intervalos de recuperação sobre o desempenho isocinético de indivíduos com doença de Parkinson
title_fullStr Efeito de diferentes intervalos de recuperação sobre o desempenho isocinético de indivíduos com doença de Parkinson
title_full_unstemmed Efeito de diferentes intervalos de recuperação sobre o desempenho isocinético de indivíduos com doença de Parkinson
title_sort efeito de diferentes intervalos de recuperação sobre o desempenho isocinético de indivíduos com doença de parkinson
publishDate 2019
url http://repositorio.unb.br/handle/10482/35247
_version_ 1641989067751030784
score 13.657419