The effect of quadriceps muscle length on maximum neuromuscular electrical stimulation evoked contraction, muscle architecture, and tendon-aponeurosis stiffness

Muscle-tendon unit length plays a crucial role in quadriceps femoris muscle (QF) physiological adaptation, but the influence of hip and knee angles during QF neuromuscular electrical stimulation (NMES) is poorly investigated. We investigated the effect of muscle length on maximum electrically induce...

Full description

Main Authors: Cavalcante, Jonathan Galvão Tenório, Marqueti, Rita de Cássia, Geremia, Jeam Marcel, Sousa Neto, Ivo Vieira de, Baroni, Bruno Manfredini, Silbernagel, Karin Gravare, Bottaro, Martim, Babault, Nicolas, Durigan, João Luiz Quagliotti
Format: Artigo
Language: Inglês
Published: Frontiers 2021
Subjects:
Online Access: https://repositorio.unb.br/handle/10482/40765
Tags: Add Tag
No Tags, Be the first to tag this record!
id ir-10482-40765
recordtype dspace
spelling ir-10482-407652021-05-03T13:25:08Z The effect of quadriceps muscle length on maximum neuromuscular electrical stimulation evoked contraction, muscle architecture, and tendon-aponeurosis stiffness Cavalcante, Jonathan Galvão Tenório Marqueti, Rita de Cássia Geremia, Jeam Marcel Sousa Neto, Ivo Vieira de Baroni, Bruno Manfredini Silbernagel, Karin Gravare Bottaro, Martim Babault, Nicolas Durigan, João Luiz Quagliotti Exercícios - fisiologia Estimulação elétrica neuromuscular Quadríceps Tendões Muscle-tendon unit length plays a crucial role in quadriceps femoris muscle (QF) physiological adaptation, but the influence of hip and knee angles during QF neuromuscular electrical stimulation (NMES) is poorly investigated. We investigated the effect of muscle length on maximum electrically induced contraction (MEIC) and current efficiency. We secondarily assessed the architecture of all QF constituents and their tendon-aponeurosis complex (TAC) displacement to calculate a stiffness index. This study was a randomized, repeated measure, blinded design with a sample of twenty healthy men aged 24.0 ± 4.6. The MEIC was assessed in four different positions: supine with knee flexion of 60° (SUP60); seated with knee flexion of 60° (SIT60); supine with knee flexion of 20° (SUP20), and seated with knee flexion of 20° (SIT20). The current efficiency (MEIC/maximum tolerated current amplitude) was calculated. Ultrasonography of the QF was performed at rest and during NMES to measure pennation angle (θp) and fascicle length (Lf), and the TAC stiffness index. MEIC and current efficiency were greater for SUP60 and SIT60 compared to SUP20 and SIT20. The vastus lateralis and medialis showed lower θp and higher Lf at SUP60 and SIT60, while for the rectus femoris, in SUP60 there were lower θp and higher Lf than in all positions. The vastus intermedius had a similar pattern to the other vastii, except for lack of difference in θp between SIT60 compared to SUP20 and SIT20. The TAC stiffness index was greater for SUP60. We concluded that NMES generate greater torque and current efficiency at 60° of knee flexion, compared to 20°. For these knee angles, lengthening the QF at the hip did not promote significant change. Each QF constituent demonstrated muscle physiology patterns according to hip and/or knee angles, even though a greater Lf and lower θp were predominant in SUP60 and SIT60. QF TAC index stiffened in more elongated positions, which probably contributed to enhanced force transmission and slightly higher torque in SUP60. Our findings may help exercise physiologist better understand the impact of hip and knee angles on designing more rational NMES stimulation strategies. 2021-05-03T13:25:08Z 2021-05-03T13:25:08Z 2021-03-29 Artigo CAVALCANTE, Jonathan Galvão Tenório et al. The effect of quadriceps muscle length on maximum neuromuscular electrical stimulation evoked contraction, muscle architecture, and tendon-aponeurosis stiffness. Frontiers in Physiology, v. 12, 633589, 29 mar. 2021. DOI: 10.3389/fphys.2021.633589. Disponível em: https://www.frontiersin.org/articles/10.3389/fphys.2021.633589/full. Acesso em: 03 maio 2021. https://repositorio.unb.br/handle/10482/40765 10.3389/fphys.2021.633589 Inglês Acesso Aberto Copyright © 2021 Cavalcante, Marqueti, Geremia, Sousa Neto, Baroni, Silbernagel, Bottaro, Babault and Durigan. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. application/pdf Frontiers
institution REPOSITORIO UNB
collection REPOSITORIO UNB
language Inglês
topic Exercícios - fisiologia
Estimulação elétrica neuromuscular
Quadríceps
Tendões
spellingShingle Exercícios - fisiologia
Estimulação elétrica neuromuscular
Quadríceps
Tendões
Cavalcante, Jonathan Galvão Tenório
Marqueti, Rita de Cássia
Geremia, Jeam Marcel
Sousa Neto, Ivo Vieira de
Baroni, Bruno Manfredini
Silbernagel, Karin Gravare
Bottaro, Martim
Babault, Nicolas
Durigan, João Luiz Quagliotti
The effect of quadriceps muscle length on maximum neuromuscular electrical stimulation evoked contraction, muscle architecture, and tendon-aponeurosis stiffness
description Muscle-tendon unit length plays a crucial role in quadriceps femoris muscle (QF) physiological adaptation, but the influence of hip and knee angles during QF neuromuscular electrical stimulation (NMES) is poorly investigated. We investigated the effect of muscle length on maximum electrically induced contraction (MEIC) and current efficiency. We secondarily assessed the architecture of all QF constituents and their tendon-aponeurosis complex (TAC) displacement to calculate a stiffness index. This study was a randomized, repeated measure, blinded design with a sample of twenty healthy men aged 24.0 ± 4.6. The MEIC was assessed in four different positions: supine with knee flexion of 60° (SUP60); seated with knee flexion of 60° (SIT60); supine with knee flexion of 20° (SUP20), and seated with knee flexion of 20° (SIT20). The current efficiency (MEIC/maximum tolerated current amplitude) was calculated. Ultrasonography of the QF was performed at rest and during NMES to measure pennation angle (θp) and fascicle length (Lf), and the TAC stiffness index. MEIC and current efficiency were greater for SUP60 and SIT60 compared to SUP20 and SIT20. The vastus lateralis and medialis showed lower θp and higher Lf at SUP60 and SIT60, while for the rectus femoris, in SUP60 there were lower θp and higher Lf than in all positions. The vastus intermedius had a similar pattern to the other vastii, except for lack of difference in θp between SIT60 compared to SUP20 and SIT20. The TAC stiffness index was greater for SUP60. We concluded that NMES generate greater torque and current efficiency at 60° of knee flexion, compared to 20°. For these knee angles, lengthening the QF at the hip did not promote significant change. Each QF constituent demonstrated muscle physiology patterns according to hip and/or knee angles, even though a greater Lf and lower θp were predominant in SUP60 and SIT60. QF TAC index stiffened in more elongated positions, which probably contributed to enhanced force transmission and slightly higher torque in SUP60. Our findings may help exercise physiologist better understand the impact of hip and knee angles on designing more rational NMES stimulation strategies.
format Artigo
author Cavalcante, Jonathan Galvão Tenório
Marqueti, Rita de Cássia
Geremia, Jeam Marcel
Sousa Neto, Ivo Vieira de
Baroni, Bruno Manfredini
Silbernagel, Karin Gravare
Bottaro, Martim
Babault, Nicolas
Durigan, João Luiz Quagliotti
author_sort Cavalcante, Jonathan Galvão Tenório
title The effect of quadriceps muscle length on maximum neuromuscular electrical stimulation evoked contraction, muscle architecture, and tendon-aponeurosis stiffness
title_short The effect of quadriceps muscle length on maximum neuromuscular electrical stimulation evoked contraction, muscle architecture, and tendon-aponeurosis stiffness
title_full The effect of quadriceps muscle length on maximum neuromuscular electrical stimulation evoked contraction, muscle architecture, and tendon-aponeurosis stiffness
title_fullStr The effect of quadriceps muscle length on maximum neuromuscular electrical stimulation evoked contraction, muscle architecture, and tendon-aponeurosis stiffness
title_full_unstemmed The effect of quadriceps muscle length on maximum neuromuscular electrical stimulation evoked contraction, muscle architecture, and tendon-aponeurosis stiffness
title_sort effect of quadriceps muscle length on maximum neuromuscular electrical stimulation evoked contraction, muscle architecture, and tendon-aponeurosis stiffness
publisher Frontiers
publishDate 2021
url https://repositorio.unb.br/handle/10482/40765
_version_ 1710449538186084352
score 13.657419