Influência de erros de protocolo da técnica autocondicionante na resistência de união à dentina

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Departamento de Odontologia, Programa de Pós-Graduação em em Odontologia, 2020.

Main Author: Brant, Amanda Ramos Rezende
Other Authors: Hilgert, Leandro Augusto
Format: Dissertação
Language: Português
Published: 2021
Subjects:
Online Access: https://repositorio.unb.br/handle/10482/41087
Tags: Add Tag
No Tags, Be the first to tag this record!
id ir-10482-41087
recordtype dspace
spelling ir-10482-410872021-06-02T14:08:24Z Influência de erros de protocolo da técnica autocondicionante na resistência de união à dentina Brant, Amanda Ramos Rezende Hilgert, Leandro Augusto Lima, Adriano Fonseca de Adesivos dentinários Dentina Resistência à tração Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Departamento de Odontologia, Programa de Pós-Graduação em em Odontologia, 2020. O objetivo do presente estudo foi avaliar a influência de possíveis erros de protocolo da técnica autocondicionante na resistência de união à dentina. 80 molares hígidos foram embutidos em resina acrílica para remoção da superfície oclusal, exposição de dentina superficial e polimento. Em seguida, divididos em grupos conforme o sistema adesivo utilizado (Clearfil SE Bond - CSE e Single Bond Universal - SBU) e protocolo adesivo com erros simulados: GC (grupo controle); GAP (aplicação passiva); GNV (ausência de volatilização do solvente); GTR (aplicação com tempo reduzido do primer - CSE ou adesivo - SBU); GTRVF (aplicação com tempo reduzido de volatilização e fotopolimerização). As superfícies foram restauradas com resina composta e seccionadas em palitos com área adesiva de 0,8mm². Metade dos espécimes foram armazenados por 24 horas em água destilada e a outra submetida a 5000 ciclos térmicos, referente a 6 meses de envelhecimento. A resistência de união foi mensurada pelo teste de microtração à velocidade de 0,5mm/min até a falha do espécime e os dados foram submetidos à análise de variância de 3-critérios de medidas repetidas e ao teste de Tukey (α=0,05). Não houve influência significativa do sistema adesivo, mas sim para o protocolo de aplicação e momento de análise. Ao qual, a ausência de volatilização do grupo GNV e momento de análise após 24h resultaram em menores valores de resistência de união. Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES). The aim of the present study was to evaluate the influence of possible protocol errors of the self etching technique on dentin bond strength. 80 healthy molars were embedded in acrylic resin to remove the occlusal surface, expose superficial dentin and polish. Then, divided into groups according to the adhesive system used (Clearfil SE Bond - CSE and Single Bond Universal - SBU) and adhesive protocol with simulated errors: GC (control group); GAP (passive application); GNV (absence of solvent volatilization); GTR (application with reduced primer time - CSE or adhesive - SBU); GTRVF (application with reduced time of volatilization and light curing). The surfaces were restored with composite resin and sectioned on toothpicks with an adhesive area of 0.8mm². Half of the specimens were stored for 24 hours in distilled water and the other was subjected to 5000 thermal cycles, referring to 6 months of aging. The bond strength was measured by the microtensile test at a speed of 0.5mm/min until the specimen fails and the data were subjected to 3-criteria analysis of variance of repeated measures and the Tukey test (α = 0.05). There was no significant influence of the adhesive system, except for the application protocol and time of analysis. The absence of volatility from the CNG group and moment of analysis after 24h resulted in lower values of bond strength 2021-06-02T14:08:24Z 2021-06-02T14:08:24Z 2021-06-02 2020-12-07 Dissertação BRANT, Amanda Ramos Rezende. Influência de erros de protocolo da técnica autocondicionante na resistência de união à dentina. 2020. 68 f., il. Dissertação (Mestrado em Odontologia)—Universidade de Brasília, Brasília, 2020. https://repositorio.unb.br/handle/10482/41087 Português Acesso Aberto application/pdf
institution REPOSITORIO UNB
collection REPOSITORIO UNB
language Português
topic Adesivos dentinários
Dentina
Resistência à tração
spellingShingle Adesivos dentinários
Dentina
Resistência à tração
Brant, Amanda Ramos Rezende
Influência de erros de protocolo da técnica autocondicionante na resistência de união à dentina
description Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Departamento de Odontologia, Programa de Pós-Graduação em em Odontologia, 2020.
author2 Hilgert, Leandro Augusto
format Dissertação
author Brant, Amanda Ramos Rezende
author_sort Brant, Amanda Ramos Rezende
title Influência de erros de protocolo da técnica autocondicionante na resistência de união à dentina
title_short Influência de erros de protocolo da técnica autocondicionante na resistência de união à dentina
title_full Influência de erros de protocolo da técnica autocondicionante na resistência de união à dentina
title_fullStr Influência de erros de protocolo da técnica autocondicionante na resistência de união à dentina
title_full_unstemmed Influência de erros de protocolo da técnica autocondicionante na resistência de união à dentina
title_sort influência de erros de protocolo da técnica autocondicionante na resistência de união à dentina
publishDate 2021
url https://repositorio.unb.br/handle/10482/41087
_version_ 1710449505609973760
score 13.657419