Dispositivo de insuflação de CO2 com controle eletrônico para a prática da endoscopia diagnóstica e terapêutica

Com os avanços na área da endoscopia digestiva, vários materiais e técnicas passaram a serem testados como forma de viabilizar o êxito dos procedimentos realizados. Uma dessas técnicas se refere ao uso de CO2 na endoscopia digestiva, que se tornou bastante usual nos últimos anos. Em contrapartida, o...

Full description

Main Author: BURITI, Juliana Grisi Lopes de Mendonça
Other Authors: LESSA, Patrícia Silva
Format: masterThesis
Language: por
Published: Universidade Federal de Pernambuco 2020
Subjects:
Online Access: https://repositorio.ufpe.br/handle/123456789/38248
Tags: Add Tag
No Tags, Be the first to tag this record!
id ir-123456789-38248
recordtype dspace
spelling ir-123456789-382482020-10-06T05:15:39Z Dispositivo de insuflação de CO2 com controle eletrônico para a prática da endoscopia diagnóstica e terapêutica BURITI, Juliana Grisi Lopes de Mendonça LESSA, Patrícia Silva BENEDETTI, Marco Aurélio http://lattes.cnpq.br/8315245746239634 http://lattes.cnpq.br/9337122145525140 http://lattes.cnpq.br/2448324832915432 Engenharia Biomédica Endoscopia digestiva Dióxido de carbono medicina Insulfador de CO2 Com os avanços na área da endoscopia digestiva, vários materiais e técnicas passaram a serem testados como forma de viabilizar o êxito dos procedimentos realizados. Uma dessas técnicas se refere ao uso de CO2 na endoscopia digestiva, que se tornou bastante usual nos últimos anos. Em contrapartida, o seu uso acarreta aumento considerável nos custos da endoscopia. Sendo assim, buscam-se formas de manter o uso do CO2, propondo a inovação de aparelhos que possam viabilizar a utilização do gás nessa área media. Este trabalho tem como objetivo geral criar um controlador eletrônico que permita lar eletronicamente o fluxo de CO2 para a prática da endoscopia, portátil, acrescido de melhorias para compatibilidade com equipamentos de diversas marcas e modelos ocasionando redução nos custos se comparado aos que estão disponíveis atualmente no mercado. Os objetivos específicos foram identificar e ar a calibragem deste dispositivo submetendo-o a um conjunto de testes s e o com instrumentos Metrologia, para garantir uma medição de fluxo em limites aceitáveis e s de medições confiáveis avaliando os resultados obtidos na calibragem metrológica considerando os valores de acertos e erros sistemáticos. Em resumo, é submetê-los a uma análise detalhada através detestes práticos metrológicos no LabCEM, Lab UFPE. Em seguida foram realizados testes de funcionamento com o instrumento. No serviço de Endoscopia Diagnóstica e Terapêutica em um hospital, obtendo bons resultados. Nos testes do equipamento foram utilizados 10 passos para o controle de fluxo, onde a variabilidade, expressa através do coeficiente de variação, se mostrou reduzida com valor máximo igual a 16,67%, que ocorreu no passo 0. Os valores da amplitude variaram de 0,02 (passo 1) a 1,40 l/m (passo 7), representando os maiores valores de erro do sistema. Pretende-se futuramente, fazer os primeiros testes em animais, mais precisamente nos porcos do Centro de Pesquisa do Hospital Sírio-Libanês, para posteriormente ser testado em humanos e, juntos aos órgãos reguladores, a comercialização do produto. With the advances in the area of the digestive endoscopy, several materials and techniques began to be tested as a way to make possible the success of the procedures performed. One of these techniques refers to the use of CO2 in digestive endoscopy, which has become quite common in recent years. On the other hand, its use leads to a considerable increase in costs of endoscopy. Therefore, we are looking for ways to maintain the use of CO2, proposing the innovation of devices that can make gas use feasible in this area of medicine. The objective of this work is to create an electronic CO2 insufflation controller that allows the electronic control of the flow of CO2 for endoscopic practice, portable and low cost, with improvements to a function of compatibility with other equipment of different makes and models costs compared to those currently available in the market. The specific objectives were to identify errors and verify the calibration of this device by subjecting it to a set of careful tests and the handling with instruments used in its manufacture through Metrology to ensure a flow measurement within acceptable limits and to obtain measurement results reliable results evaluating the results obtained in the metrological calibration considering the values of correct and systematic errors. In summary, it is submitted to a detailed analysis through practical metrological tests with the device created in LabCEM, Laboratory of Electronic Engineering of UFPE. Then, the instrument was tested for performance. In the construction of the equipment were applied the concepts of metrology using a flow analyzer to carry out the measurement of the same and, afterwards, were performed functional tests in the service of Diagnostic and Therapeutic Endoscopy in a hospital, obtaining good results. In the equipment tests, 10 steps were used for flow control, where the variability, expressed through the coefficient of variation, was reduced with a maximum value equal to 16.67%, which occurred in step 0. Amplitude values varied from 0.02(step 1) to 1.40 l / m (step 7), representing the highest system error values. In the future, it is intended to do the first tests on animals, more precisely on the pigs of the Research Center of the Sírio-Libanês Hospital, to be later tested in humans and try, together with the regulatory agencies, the commercialization of the product. 2020-10-05T20:43:55Z 2020-10-05T20:43:55Z 2019-08-23 masterThesis BURITI, Juliana Grisi Lopes de Mendonça. Dispositivo de insuflação de CO2 com controle eletrônico para a prática da endoscopia diagnóstica e terapêutica. 2019. Dissertação (Mestrado em Engenharia Biomédica) - Universidade Federal de Pernambuco, Recife, 2019. https://repositorio.ufpe.br/handle/123456789/38248 por embargoedAccess http://creativecommons.org/licenses/by-nc-nd/3.0/br/ application/pdf Universidade Federal de Pernambuco UFPE Brasil Programa de Pos Graduacao em Engenharia Biomedica
institution REPOSITORIO UFPE
collection REPOSITORIO UFPE
language por
topic Engenharia Biomédica
Endoscopia digestiva
Dióxido de carbono medicina
Insulfador de CO2
spellingShingle Engenharia Biomédica
Endoscopia digestiva
Dióxido de carbono medicina
Insulfador de CO2
BURITI, Juliana Grisi Lopes de Mendonça
Dispositivo de insuflação de CO2 com controle eletrônico para a prática da endoscopia diagnóstica e terapêutica
description Com os avanços na área da endoscopia digestiva, vários materiais e técnicas passaram a serem testados como forma de viabilizar o êxito dos procedimentos realizados. Uma dessas técnicas se refere ao uso de CO2 na endoscopia digestiva, que se tornou bastante usual nos últimos anos. Em contrapartida, o seu uso acarreta aumento considerável nos custos da endoscopia. Sendo assim, buscam-se formas de manter o uso do CO2, propondo a inovação de aparelhos que possam viabilizar a utilização do gás nessa área media. Este trabalho tem como objetivo geral criar um controlador eletrônico que permita lar eletronicamente o fluxo de CO2 para a prática da endoscopia, portátil, acrescido de melhorias para compatibilidade com equipamentos de diversas marcas e modelos ocasionando redução nos custos se comparado aos que estão disponíveis atualmente no mercado. Os objetivos específicos foram identificar e ar a calibragem deste dispositivo submetendo-o a um conjunto de testes s e o com instrumentos Metrologia, para garantir uma medição de fluxo em limites aceitáveis e s de medições confiáveis avaliando os resultados obtidos na calibragem metrológica considerando os valores de acertos e erros sistemáticos. Em resumo, é submetê-los a uma análise detalhada através detestes práticos metrológicos no LabCEM, Lab UFPE. Em seguida foram realizados testes de funcionamento com o instrumento. No serviço de Endoscopia Diagnóstica e Terapêutica em um hospital, obtendo bons resultados. Nos testes do equipamento foram utilizados 10 passos para o controle de fluxo, onde a variabilidade, expressa através do coeficiente de variação, se mostrou reduzida com valor máximo igual a 16,67%, que ocorreu no passo 0. Os valores da amplitude variaram de 0,02 (passo 1) a 1,40 l/m (passo 7), representando os maiores valores de erro do sistema. Pretende-se futuramente, fazer os primeiros testes em animais, mais precisamente nos porcos do Centro de Pesquisa do Hospital Sírio-Libanês, para posteriormente ser testado em humanos e, juntos aos órgãos reguladores, a comercialização do produto.
author2 LESSA, Patrícia Silva
format masterThesis
author BURITI, Juliana Grisi Lopes de Mendonça
author_sort BURITI, Juliana Grisi Lopes de Mendonça
title Dispositivo de insuflação de CO2 com controle eletrônico para a prática da endoscopia diagnóstica e terapêutica
title_short Dispositivo de insuflação de CO2 com controle eletrônico para a prática da endoscopia diagnóstica e terapêutica
title_full Dispositivo de insuflação de CO2 com controle eletrônico para a prática da endoscopia diagnóstica e terapêutica
title_fullStr Dispositivo de insuflação de CO2 com controle eletrônico para a prática da endoscopia diagnóstica e terapêutica
title_full_unstemmed Dispositivo de insuflação de CO2 com controle eletrônico para a prática da endoscopia diagnóstica e terapêutica
title_sort dispositivo de insuflação de co2 com controle eletrônico para a prática da endoscopia diagnóstica e terapêutica
publisher Universidade Federal de Pernambuco
publishDate 2020
url https://repositorio.ufpe.br/handle/123456789/38248
_version_ 1680625273748324352
score 13.657419