Glittre ADL-Test na avaliação da capacidade funcional de indivíduos adultos com insuficiência cardíaca

A insuficiência cardíaca (IC) é uma síndrome cardiovascular com impacto na saúde pública, leva a redução da capacidade funcional, limitando a execução de atividades de vida diária e de exercícios físicos. Considerada de grande importância, a capacidade funcional pode ser avaliada por uma variedad...

Full description

Main Author: LEITE, Jéssica Costa
Other Authors: BRANDÃO, Daniella Cunha
Format: masterThesis
Language: por
Published: Universidade Federal de Pernambuco 2017
Subjects:
Online Access: https://repositorio.ufpe.br/handle/123456789/18732
Tags: Add Tag
No Tags, Be the first to tag this record!
id ir-123456789-18732
recordtype dspace
spelling ir-123456789-187322018-10-03T21:12:51Z Glittre ADL-Test na avaliação da capacidade funcional de indivíduos adultos com insuficiência cardíaca LEITE, Jéssica Costa BRANDÃO, Daniella Cunha BRANDÃO, Simone Cristina Soares RESQUETI, Vanessa Regiane http://lattes.cnpq.br/7183002036766876 http://lattes.cnpq.br/4774435440649537 Sensibilidade e especificidade Tolerância ao exercício Atividades cotidianas Insuficiência cardíaca Sensitivity and specificity Heart Failure Exercise Tolerance Activities of Daily Living A insuficiência cardíaca (IC) é uma síndrome cardiovascular com impacto na saúde pública, leva a redução da capacidade funcional, limitando a execução de atividades de vida diária e de exercícios físicos. Considerada de grande importância, a capacidade funcional pode ser avaliada por uma variedade de instrumentos, tais como questionários e testes de campo, sendo o Teste de exercício cardiopulmonar considerado o padrão ouro. O Glittre ADL-Test, é um teste funcional submáximo que busca representar as atividades do cotidiano, uma vez que envolve um conjunto de tarefas comuns na vida diária. Esta dissertação está estruturada sob a forma de dois artigos originais. O primeiro artigo teve como objetivo avaliar e estabelecer um valor de diagnóstico para o Glittre ADL-Test em indivíduos adultos com Insuficiência Cardíaca, quando comparado ao padrão ouro. Foi realizado análise de acurácia do tempo de realização do Glittre ADL-Test em comparação com o VO2pico dado pelo TECP, utilizando o ponto de corte para o VO2pico de 16 ml/Kg/min a partir da classificação de Weber. O melhor ponto de corte encontrado foi de 258 segundos, com sensibilidade de 88,89% (IC 95%, 65,29-98,62) e especificidade de 70% (IC 95%, 45,72-88,11), com área sob a curva de 0,80 (IC 95% 0,66-0,94 e p 0,001). A prevalência encontrada no estudo para baixa capacidade funcional (VO2pico < 16 ml/Kg/min-1) foi de 47,3%, e para um TTotal maior que 258 segundos encontramos VPP de 72,73% (IC 95%, 49,78-89,2) e VPN de 87,50% (IC 95%, 61,65-98,4). A RV positiva para o ponto de corte de 258 segundos foi de 2,96 (IC 95% 1,49-5,90), e a RV negativa foi de 0,16 (IC 95% 0,04-0,60), resultando em um pós-teste positivo de 73% e negativo de 12%. O segundo artigo teve como objetivo investigar se o tempo necessário para realização do Glittre ADL-Test varia de acordo com a classificação de Weber para o VO2 pico, e sua correlação com a força muscular respiratória, função pulmonar e mobilidade diafragmática. O tempo médio de realização do Glittre ADLTest foi de 286,5 segundos, houve diferença significativa entre as classes A (254,1 segundos) e C (324 segundos) de Weber (p<0,05). O Glittre ADL-Test mostrou correlações significativas com a PImáx (r=-0,445 – p<0,01), com a PEmáx (r=-0,531 – p<0,01) e com a mobilidade diafragmática (r=-0,361 – p<0,05). Vinte e oito pacientes realizaram um segundo teste, na análise de reprodutibilidade, o ICC encontrado foi de 0,76 (IC 95% 0,17-0,91) e p<0,01. Conclusão: Os valores de sensibilidade, especificidade, VPP e VPN, mostraram que o Glittre ADL-Test é acurado na avaliação da capacidade funcional de pacientes com IC. É útil e pode ser usado na prática clínica, pois também se mostrou capaz de refletir a performance funcional destes indivíduos e apresentou correlação com a força muscular respiratória e mobilidade diafragmática. CAPES Heart failure (HF) is a cardiovascular syndrome with enormous impact on public health, leading to reduced functional capacity in terms of both physical limitations to activities of daily living as well as the implementation of physical exercises. Considered of great importance, functional capacity can be assessed by a variety of instruments such as questionnaires and field tests, and cardiopulmonary exercise test considered the gold standard. The Glittre ADL-Test is a submaximal functional test that seeks to represent the daily activities, since it involves a set of common tasks in everyday life. This paper is structured in the form of two original articles. The first article was to evaluate and establish a diagnostic value for the Glittre ADL-Test in adults with heart failure when compared to the gold standard was carried out accuracy analysis of the Glittre ADLTest performance time compared to the data peak VO2 CPX by using the cutoff point for the peak VO2 of 16 ml/kg/min from the Weber classification. The best cutoff point was of 258 second, with a sensitivity of 88.89% (95% CI 65.29 to 98.62) and a specificity of 70% (95% CI 45.72 to 88.11) with an area under the curve of 0.80 (95% CI 0.66 to 0.94 and p 0.001). The prevalence found in the study to low functional capacity (peak VO2 <16 ml / kg / min) was 47.3%, and for TTotal greater than 258 seconds found PPV of 72.73% (95% CI, 49, 78 to 89.2) and VPN 87.50% (95% CI, 61.65 to 98.4). The positive LR to the cutoff point of 258 seconds, it was 2.96 (95% CI 1.49 to 5.90) and the negative LR was 0.16 (95% CI 0.04 to 0.60) resulting in a positive post-test of 73% and negative 12%. The second study aimed to investigate whether the time required to perform the Glittre ADL-Test varies according to Weber's rating for the peak VO2, and its correlation with respiratory muscle strength, pulmonary function and diaphragmatic mobility. The mean duration of the Glittre ADL-Test was 286.5 seconds there was a significant difference between the classes (254.1 seconds) and C (324 seconds) Weber (p <0.05). The Glittre ADL-Test showed significant correlations with MIP (r=-0.445 - p <0.01), with the MEP (r = -0.531 - p <0.01) and diaphragmatic mobility (r=-0.361 - p <0.05). Twenty-eight patients underwent a second test, the reproducibility of analysis, the ICC found was 0.76 (95% CI 0.17 to 0.91) and p <0.01. Conclusion: The sensitivity, specificity, PPV and NPV, showed that the Glittre ADLTest is accurate in assessing the functional capacity of patients with HF. It is useful and can be used in clinical practice, he was also able to reflect the functional performance of these individuals and correlated with respiratory muscle strength and diaphragmatic mobility. 2017-05-08T14:50:09Z 2017-05-08T14:50:09Z 2016-05-27 masterThesis https://repositorio.ufpe.br/handle/123456789/18732 por Attribution-NonCommercial-NoDerivs 3.0 Brazil http://creativecommons.org/licenses/by-nc-nd/3.0/br/ Universidade Federal de Pernambuco UFPE Brasil Programa de Pos Graduacao em Fisioterapia
institution REPOSITORIO UFPE
collection REPOSITORIO UFPE
language por
topic Sensibilidade e especificidade
Tolerância ao exercício
Atividades cotidianas
Insuficiência cardíaca
Sensitivity and specificity
Heart Failure
Exercise Tolerance
Activities of Daily Living
spellingShingle Sensibilidade e especificidade
Tolerância ao exercício
Atividades cotidianas
Insuficiência cardíaca
Sensitivity and specificity
Heart Failure
Exercise Tolerance
Activities of Daily Living
LEITE, Jéssica Costa
Glittre ADL-Test na avaliação da capacidade funcional de indivíduos adultos com insuficiência cardíaca
description A insuficiência cardíaca (IC) é uma síndrome cardiovascular com impacto na saúde pública, leva a redução da capacidade funcional, limitando a execução de atividades de vida diária e de exercícios físicos. Considerada de grande importância, a capacidade funcional pode ser avaliada por uma variedade de instrumentos, tais como questionários e testes de campo, sendo o Teste de exercício cardiopulmonar considerado o padrão ouro. O Glittre ADL-Test, é um teste funcional submáximo que busca representar as atividades do cotidiano, uma vez que envolve um conjunto de tarefas comuns na vida diária. Esta dissertação está estruturada sob a forma de dois artigos originais. O primeiro artigo teve como objetivo avaliar e estabelecer um valor de diagnóstico para o Glittre ADL-Test em indivíduos adultos com Insuficiência Cardíaca, quando comparado ao padrão ouro. Foi realizado análise de acurácia do tempo de realização do Glittre ADL-Test em comparação com o VO2pico dado pelo TECP, utilizando o ponto de corte para o VO2pico de 16 ml/Kg/min a partir da classificação de Weber. O melhor ponto de corte encontrado foi de 258 segundos, com sensibilidade de 88,89% (IC 95%, 65,29-98,62) e especificidade de 70% (IC 95%, 45,72-88,11), com área sob a curva de 0,80 (IC 95% 0,66-0,94 e p 0,001). A prevalência encontrada no estudo para baixa capacidade funcional (VO2pico < 16 ml/Kg/min-1) foi de 47,3%, e para um TTotal maior que 258 segundos encontramos VPP de 72,73% (IC 95%, 49,78-89,2) e VPN de 87,50% (IC 95%, 61,65-98,4). A RV positiva para o ponto de corte de 258 segundos foi de 2,96 (IC 95% 1,49-5,90), e a RV negativa foi de 0,16 (IC 95% 0,04-0,60), resultando em um pós-teste positivo de 73% e negativo de 12%. O segundo artigo teve como objetivo investigar se o tempo necessário para realização do Glittre ADL-Test varia de acordo com a classificação de Weber para o VO2 pico, e sua correlação com a força muscular respiratória, função pulmonar e mobilidade diafragmática. O tempo médio de realização do Glittre ADLTest foi de 286,5 segundos, houve diferença significativa entre as classes A (254,1 segundos) e C (324 segundos) de Weber (p<0,05). O Glittre ADL-Test mostrou correlações significativas com a PImáx (r=-0,445 – p<0,01), com a PEmáx (r=-0,531 – p<0,01) e com a mobilidade diafragmática (r=-0,361 – p<0,05). Vinte e oito pacientes realizaram um segundo teste, na análise de reprodutibilidade, o ICC encontrado foi de 0,76 (IC 95% 0,17-0,91) e p<0,01. Conclusão: Os valores de sensibilidade, especificidade, VPP e VPN, mostraram que o Glittre ADL-Test é acurado na avaliação da capacidade funcional de pacientes com IC. É útil e pode ser usado na prática clínica, pois também se mostrou capaz de refletir a performance funcional destes indivíduos e apresentou correlação com a força muscular respiratória e mobilidade diafragmática.
author2 BRANDÃO, Daniella Cunha
format masterThesis
author LEITE, Jéssica Costa
author_sort LEITE, Jéssica Costa
title Glittre ADL-Test na avaliação da capacidade funcional de indivíduos adultos com insuficiência cardíaca
title_short Glittre ADL-Test na avaliação da capacidade funcional de indivíduos adultos com insuficiência cardíaca
title_full Glittre ADL-Test na avaliação da capacidade funcional de indivíduos adultos com insuficiência cardíaca
title_fullStr Glittre ADL-Test na avaliação da capacidade funcional de indivíduos adultos com insuficiência cardíaca
title_full_unstemmed Glittre ADL-Test na avaliação da capacidade funcional de indivíduos adultos com insuficiência cardíaca
title_sort glittre adl-test na avaliação da capacidade funcional de indivíduos adultos com insuficiência cardíaca
publisher Universidade Federal de Pernambuco
publishDate 2017
url https://repositorio.ufpe.br/handle/123456789/18732
_version_ 1641987036834430976
score 13.657419